PLASMODIUM FALCIPARUM INFECTION IN FEBRILE CONGOLESE CHILDREN: PREVALENCE OF CLINICAL MALARIA TEN YEARS AFTER INTRODUCTION OF ARTEMISININ-COMBINATION THERAPIES
  1. Mandingha Kosso Etoka-Beka1,
  2. Francine Ntoumi1,
  3. Michael Kombo1,
  4. Julia Deibert2,
  5. Pierre Poulain1,
  6. Christevy Vouvoungui1,
  7. Simon Kobawila3,
  8. Félix Koukouikila-Koussounda1
  1. 1FCRM, Republic of Congo
  2. 2ITM Tübingen, Germany
  3. 3Université Marien Ngouabi, Republic of Congo

Abstract

Background The detailed assessment of the QT and corrected QT interval prolongation is recommended when testing new drugs. Generally the electrocardiograph automatically displays reliable values of the QT interval and corrected QT but morphological variations of the T wave may cause reading errors; hence the use of manual measurement as an alternative method. Our objective was to evaluate the correlation between the automatic and manual measurement of QT values.

Methods In Kolle from March 2012 to December 2015, an open randomised, phase III-b/IV study comparing dihydroartemisinine-piperaquine and pyronaridine-artesunate artemether-lumefantrine was conducted. An electrocardiograph cartridge with 12 electrodes coupled to a computer with the Tele Touch software was used for the electrocardiogram on Day 0 before the study drugs administration and on Day 2, two to four hours after the administration of the last dose of the antimalarial. The manual measurement of QT and QTc was made using the Bazett method [QTcB_m=(Number leaded×0.04×QTcF) / QTcB]. For prolonged QTc cases on Day 2, another measurement was done during the next scheduled visit (day 7, 14, 21, 28, 35 and 42) until the QTc normalised.

Results A total of 764 ECG were recorded with 398 participants. Different automatic and manual values of QT and QTc are scattered around different medium. Comparisons of different values of QT: p=0.1245 and QTc: p< 0.001 showed statistically significant differences and the concordance between automatic and manual tests was (QT: Rho_c=0.77 and QTc: Rho_c=0.46).

Conclusions Our results indicate no perfect match between automatic and manual methods for QT and QTc. Manual reading remains important to correct any machine errors during clinical studies.

This is an Open Access article distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/